Files
L363-Fortbildung-ABC-CBRN-E…/Trainings/CoMo-170_ZS-2/story_content/5YHZdvAmM1F_captions.js
T

1 line
1.2 KiB
JavaScript

window.globalProvideData('caption', '{"data":"WEBVTT%0D%0AKind:%20captions%0D%0ASource:%20Articulate%20Closed%20Captions%20Editor%0D%0ASource%20Version:%203.98.34263.0%0D%0A%0D%0A00:00:00.150%20--%3E%2000:00:04.112%0D%0ALiegen%20die%20Impulsraten%20f%C3%BCr%20den%20Alpha%20Kanal%20bei%20gr%C3%B6%C3%9Fer%200,5%20I%20P%20S%0D%0A%0D%0A00:00:04.262%20--%3E%2000:00:08.225%0D%0Aoder%20die%20Impulsraten%20f%C3%BCr%20den%20beta%20Gamma%20Kanal%20bei%20gr%C3%B6%C3%9Fer%2030%20I%20P%20S%20so%0D%0A%0D%0A00:00:08.375%20--%3E%2000:00:12.342%0D%0Asollten%20Sie%20das%20Ger%C3%A4t%20nicht%20in%20den%20Einsatz%20bringen!%0D%0AIn%20diesem%20Fall%20ergab%20die%0D%0A%0D%0A00:00:12.492%20--%3E%2000:00:16.617%0D%0Aerste%20Nulleffektmessung%20f%C3%BCr%20den%20Alpha%20Kanal%200,0%20und%20f%C3%BCr%20den%20Beta%20und%20Gamma%0D%0A%0D%0A00:00:16.767%20--%3E%2000:00:20.884%0D%0AKanal%2019,6%20I%20P%20S.%0D%0ADie%20zweite%20Nulleffektmessung%0D%0A%0D%0A00:00:21.034%20--%3E%2000:00:25.052%0D%0Aergab%20die%20Werte%200,0%20und%2020,3%20I%20P%20S.%0D%0ADie%0D%0A%0D%0A00:00:25.202%20--%3E%2000:00:29.806%0D%0APr%C3%BCfung%20ist%20bestanden.%20Sie%20k%C3%B6nnen%20das%20Ger%C3%A4t%20nun%20in%20den%20Einsatz%20bringen.%0D%0A%0D%0A"}')